5. Remove the hard drive as described in your server’s service manual.
6. Install a new hard drive as described in your server’s service manual.
7. Configure the new hard drive. Type:
For example:
The green Activity LED flashes as the new disk at c0t3d0 is added to the device
tree.
8. Verify that the new hard drive is in the device tree. Type:
Note that c0t3d0 is now listed as configured.
Related Information
“Hot-Plug a Mirrored Disk” on page 23
“Delete a Hardware RAID Volume” on page 21
usb0/1 unknown empty unconfigured ok
usb0/2 unknown empty unconfigured ok
#
# cfgadm -c configure Ap-Id
# cfgadm -c configure c1::dsk/c0t3d0
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 scsi-bus connected configured unknown
c0::dsk/c0t0d0 disk connected configured unknown
c0::dsk/c0t1d0 disk connected configured unknown
c0::dsk/c0t2d0 disk connected configured unknown
c0::dsk/c0t3d0 disk connected configured unknown
c1 scsi-bus connected configured unknown
c1::dsk/c1t0d0 CD-ROM connected configured unknown
usb0/1 unknown empty unconfigured ok
usb0/2 unknown empty unconfigured ok
#