Fujitsu T5440 Server User Manual


 
30 SPARC Enterprise T5440 Server Administration Guide July 2009
2. At the ILOM -> prompt, type:
The system is set to run full POST diagnostics on system reset.
3. To return to your normal diagnostic settings after running POST, type:
Related Information
“Clearing Faults” on page 33
“Bypassing Minor Faults” on page 31
“Managing Devices” on page 34
“Locate the System” on page 30
Locate the System
1. Log in to ILOM.
See “Log In to ILOM” on page 28.
2. To easily find your system in a data center or server room, use the Locator LED
as described below.
To turn on the Locator LED, from the ILOM -> prompt, type:
To turn off the Locator LED, from the ILOM -> prompt, type:
To display the state of the locator LED, from the ILOM -> prompt, type:
For more information on LEDs, see your server’s service manual.
Related Information
“Configure a Device Manually” on page 35
“Clear Component Fault Messages” on page 34
-> set /SYS keyswitch_state=diag
-> set /SYS keyswitch_state=normal
-> set /SYS/LOCATE value=Fast_Blink
-> set /SYS/LOCATE value=off
-> show /SYS/LOCATE