HP (Hewlett-Packard) 2103R-CSDI Switch User Manual


 
4-4
C
H
A
P
T
E
R
4:
M
O
N
I
T
O
R
I
N
G
E
D
G
E
R
O
U
T
E
R
M
O
D
U
L
E
O
P
E
R
A
T
I
O
N
Using the SHOW
MODULE Command
The SHOW MODULE command displays information about a specific
module.
The syntax for the SHOW MODULE command is:
SHOW MODULE
slot
{verbose}
{no_verbose}
The following command displays verbose information for an Edge Router
module installed in slot 1 of an ONcore hub:
ONcore> show module 1.1 verbose
Slot Module Version Network General Information
----- --------- ------- ------- ----------------
01.01 6102M-SDEK v1.00 PER_PORT 2103R-CSDI
6102M-SDEK: ONcore ONdeck Ethernet Carrier Module
Boot Version: v1.00
ENGINE 1 Model Number: 2103R-CSDI
Description: Edge Rtr DIBMSW
Expansion Module Model Number:
Native Software Version: v10.03
Native Boot Software Version: v4.14
IP Default Gateway: 0.0.0.0
Mailbox Version: 0.00.0
No. Backplane Ports: 1
No. Front Ports: 2
Engine Status: OKAY
NVRAM Dip Switch State: DISABLED
Module Capabilities: MACCFG;IPCFG;
ENGINE 2 Model Number: NOT INSTALLED
Description:
Expansion Module Model Number:
Native Software Version:
Native Boot Software Version:
IP Default Gateway: 0.0.0.0
Mailbox Version: 0.00.0
No. Backplane Ports: 4
No. Front Ports: 0
Engine Status: NOT INSTALLED
NVRAM Dip Switch State: DISABLED
Module Capabilities: -NONE-