HP (Hewlett-Packard) 3080 Personal Computer User Manual


 
Small Form Factor
Table D-3 Specifications – HP Pro 3000/3080 Small Form Factor
Desktop Dimensions
Height
Width
Depth
3.98 in
13.35 in
15.24 in
101 mm
339 mm
387 mm
Approximate Weight 14.95 lb 6.81 kg
Temperature Range
Operating
Nonoperating
50° to 95°F
-22° to 140°F
10° to 35°C
-30° to 60°C
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
10-90%
5-95%
10-90%
5-95%
Maximum Altitude (unpressurized)
Operating
Nonoperating
10,000 ft
30,000 ft
3048 m
9144 m
NOTE: Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no
direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and
number of options installed.
Heat Dissipation
Maximum
For 115V/60Mhz
250W PFC HV TFX:
173.9W or 593.35 BTU/
hr
250W PFC TFX:
179.2W or 611.43 BTU/
hr
For 230V/50Hz
250W PFC HV TFX:
172.3W or 587.89
BTU/hr 250W PFC
TFX:
174.8W or 596.42
BTU/hr
Typical (idle) For 115V/60Mhz
250W PFC HV TFX:
51.9W or 177.0828 BTU/
hr
250W PFC TFX:
52.8W or 180.1536 BTU/
hr
For 230V/50Hz
250W PFC HV TFX:
51.4W or 175.3768
BTU/hr
250W PFC TFX:
53.3W or 181.8596
BTU/hr
Power Supply
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
115V
90-132 VAC
100-127 VAC
50-60 Hz
230V
180-264 VAC
200-240 VAC
50-60 Hz
180 Appendix D Specifications