HP (Hewlett-Packard) AA-RSB6B-TE Switch User Manual


 
Installing the SAN Switch 2/8
25hp StorageWorks SAN Switch 2/8 Installation Guide
Four Switch Limitation CLI Error Messages
If the fabric detects that the four switch limitation has been exceeded, the
following message occurs every thirty seconds, via the Command Line Interface
(CLI), as follows:
CRITICAL FABRIC-SIZE_EXCEEDED, 1, Critical fabric size <8>
exceeds supported configuration <4>. Switch status marginal.
Contact Technical Support.
WebTools will be disabled in 39 days 8 hours and 46 minutes.
The switch warning messages may be stored in the Syslog. Third party application
SNMP traps may be configured on the switch.
Four Switch Limitation Web Tools Error Messages
If the fabric detects that the number of switches installed exceeds the four switch
limit, Web Tools displays a warning message every 75 seconds (not configurable).
Figure 3 shows a typical Web Tools Warning Message.
Figure 3: Four switch limitation Web Tools error message
Note: The SAN Switch 2/8 EL displays a separate error condition warning message in
the dialog box.