HP (Hewlett-Packard) AA-RSB6B-TE Switch User Manual


 
Installing the SAN Switch 2/8
53hp StorageWorks SAN Switch 2/8 Installation Guide
Committing configuration...Done
7. At the prompt type, SwitchEnable.
8. After setting the Core PID to match the the other switches in the fabric, go to
the “Connecting the SAN Switch 2/8 to the LAN” section on page 50 in this
chapter, for instructions on connecting Fibre Channel cables.
9. If necessary, type cfgEnable to re-establish zoning.
Note: Once the switch PID format is set, it is stored in the flash memory of the switch
and it is NOT necessary to set it again during subsequent firmware upgrades.
Modifying Domain IDs
Optional. Modify the domain IDs if desired, as follows.
Note: It is best to assign a unique domain ID prior to connecting the switch to other
switches in the SAN. This eliminates the possibility of domain ID overlap.The default
domain ID is 1. If the default domain ID is already in use when the switch is connected
to the fabric, the domain ID for the new switch is automatically reset to a unique value.
The domain IDs that are currently in use can be determined using the telnet command,
fabricShow.
1. To disable the switch, type:
switchDisable
2. Enter the following:
configure