HP (Hewlett-Packard) rx4610 Server User Manual


 
Chapter 10: Configuring the HP Server
96
EMP Feature
Description
Access Mode Set the times during system operation when EMP access
over the specified port is available. The choices are:
Pre-boot only. The EMP is automatically activated
when the system is powered off and during POST.
Always Active. The serial port is always dedicated
for EMP use.
Always Disabled. The EMP is deactivated.
Restricted Access
Mode
Enables or disables restricted mode access. When
restricted mode is enabled, control operations that could
disable or alter a running system via the EMP are
disabled.
Connection Mode Configures the method to connect to the EMP:
Direct Connect Mode is for applications that
connect the EMP port directly to another computer
system.
Modem Mode is for applications that connect the
EMP port to an external modem.
Data Carrier
Detect (DCD)
Mode
Enables or disables monitoring of the Data Carrier Detect
(DCD) signal. When DCD Mode is enabled, the EMP is
activated and/or reinitialized whenever the serial port's
DCD signal becomes de-asserted.
Baud Rate Configures the maximum rate in bits per second that data
is transmitted through the EMP port. Baud rates are
19200, 38400, 57600, and 115200.
Flow Control You can disable the flow control or set it to CTS/RTS.
Modem Init String The initialization string is transmitted every time the
EMP initializes. The maximum length is 32 bytes and it
is usually set to "ATE1Q0V1X4&D2&C1S0=0".
Modem Hangup
String
The Hangup String is sent to the modem when the EMP
terminates the session. The EMP automatically sends an
<Enter> character after this string. The maximum
length is 8 bytes and it is usually set to "ATH".
Modem ESC
Sequence
The Modem ESC Sequence string is sent to the modem
before sending a command string to the modem. The
maximum length is 8 bytes and it is usually set to "+++".
Modem Phone
Number
Enter the phone number of the modem connected to this
server. The maximum length is 32 bytes. The Modem
Phone Number can be retrieved and reported via in-band
management connections.