HP (Hewlett-Packard) unix workstation Personal Computer User Manual


 
Chapter 3 69
Troubleshooting
Selftest Failures
INI 91DB IO BD init SERIAL_LDB
Initializing serial LDB port as console
display.
INI 9C51 IO BD consol is SER_1
Console display is on serial port 1.
WRN 9C51 IO BD bad init SERIAL1
Serial port 1 failed to initialize as a
console device.
INI 9C52 IO BD consol is SER_2
Console display is on serial port 2.
WRN 9C52 IO BD bad init SERIAL2
Serial port 2 failed to initialize as a
console device.
INI 9C6
s
EXT IO consol is GRAPH
s
Console display is on graphics card in PCI
slot s.
WRN 9C6
s
EXT IO bad PCI slot
s
Graphics in PCI slot s failed to initialize
as a console device.
INI 9C8
t
EXT IO cnfg mon type
t
Set graphics console to monitor type t.
(Seen when cycling through types.)
WRN 9C8
t
EXT IO mon type
t
fail
Failed to configure console to monitor type
t.
INI 9CDB IO BD consl is SER_LDB
Console display is on serial LDB port.
WRN 9CDB IO BD bad init SER_LDB
Serial LDB port failed to initialize as a
console device.
FLT A088 IO BD consl path fault
Unable to boot--no console device found.
WRN A008 EXT IO no boot device
Unable to boot--no bootable device found.
WRN A0BD EXT IO device not ready
Boot device not ready--operation may be
retried.
FLT A0FF EXT IO unknown launch
Unable to boot. Explanation may appear
on console.
WRN A50F EXT IO init pri pth err
Unable to boot from primary boot device.
WRN A70F EXT IO init otr pth err
Unable to boot from non-primary boot
device.
INI C10
m
SYS BD CPU
m
is monarch
CPU m was chosen as the monarch
processor. (All other CPUs are slaves.)
INI C30
m
SYS BD monarch
m
test
CPU m finished the monarch-only tests
and system initialization.
INI C30C SYS BD mnrch slv chck
The monarch CPU is checking whether
the slaves are in the correct rendezvous.
Table 3-2. Chassis Codes for the B2000 Workstation
Ostat Code FRU Message
Description