Honeywell 6100 Laptop User Manual


 
11 - 5
Charging the Main Battery
The base provides power to the Dolphin terminals and allows the
charging of the main batteries in the terminals. The main battery of
each terminal charges in 4 hours for the standard 3.7V battery or
6 hours for the extended 3.7V battery. The intelligent battery charging
system incorporated into all Dolphin terminals prevents overcharging,
which means that Dolphin terminals may be stored in the base indefi-
nitely without damage to the terminals, battery packs, or the base.
To Power a Terminal and Charge its Main Battery
1. Install the main battery pack in the terminal; see Install the Main Battery on page 2-1.
2. Verify the base has power. If the Power/Dock LEDs are not illuminated, see Connecting Power to
the Net Base on page 11-4.
3. Slide the Dolphin terminal into one of the four terminal wells. The the Power/Dock LED for the well
changes to green. Charging begins immediately if required by the Dolphin terminal.
We recommend use of Honeywell peripherals, power cables, and power adapters. Use of any non-Honeywell
peripherals, cables, or power adapters may cause damage not covered by the warranty.
We recommend use of Honeywell Li-Ion battery packs. Use of any non-Honeywell battery may result in
damage not covered by the warranty.
Ensure all components are dry prior to mating batteries with peripheral devices. Mating wet components may
cause damage not covered by the warranty.
Communication
Software Requirements
Before you connect the Dolphin terminal to the Net Base, make sure you have the most current software
installed. To check the terminal’s system information, tap > Power Tools > SysInfo.
The Kernel version must be 28.04 or later in terminals running Windows Embedded Handheld 6.5
Classic.
In terminals running Windows CE 5.0, the kernel version must be 23.08 Service Pack 8 or later.
Applications on the Dolphin Terminal
Applications running on the Dolphin terminal when it is connected to the Net Base should be designed
specifically for a partially connected network. For more details, please refer to the Best Practices for Par-
tially Connected Networks document available at www.honeywellaidc.com.
Connecting the Dolphin Terminal to the Net Base
By default, the Dolphin terminal is configured to obtain IP addresses automatically using a DHCP server.
This means that in most cases, you would simply plug-and-play the unit.
!
!
!!