Honeywell Switches and Sensors Switch User Manual


 
100
www.honeywell.com/sensing
LINEAR AND ROTARY POSITION
MLT Series
Linear position transducer, 3/8 in Diameter
The MLT Series is 3/8 in diameter linear position transducer that is rugged
enough to withstand hostile factory environments. Using a proprietary dual
wiper, internal ball joint and the MystR
®
conductive plastic film the MLT
provides a usable output at high vibration levels over long periods of time.
MLT transducers use precious metal wipers to further enhance reliability.
The MLT’s 3/8 inch diameter is among the smallest available and can used to
replace LVDT’s in many applications.
Operating temperature: -40 °C to 80 °C (-40 °F to 176 °F)
Supply voltage (max.): 30 Vdc
Starting force (max.): 28,35 g (1.0 oz)
Backlash (max.): 0,0127 mm (0.0005 in)
Shaft Ø: 1/8 in
Termination: Cable
Housing length: = Electrical travel + 1.20 in (30,48 mm)
Mechanical travel: = Electrical travel + 0.05 in (1,27 mm)
Electrical Travel Total Resistance
(in (mm)) (Ohm)
MLT0R5 0.5 (12,7) 750
MLT001 1.0 (25,4) 1500
MLT002 2.0 (50,8) 3000
MLT003 3.0 (76,2) 4500
MLT004 4.0 (101,6) 6000
MLT005 5.0 (127,0) 7500
MLT006 6.0 (152,4) 9000
(Retracted)
#4-40 UNC-2A
Thd x .50 [12,7] long
3/4"
[19,05]
1/8"
[3,18]
3/8"
[9,53]
(Electrical Travel +1.2 [30,48])
(Red)
V- i n
Shaft
Extended
(Black)
Ground
(Orange)
V- out
Housing length 'X'
Connect to High Impedance Circuit
3 - conductor cable
#26 AWG [65/44] 12.0 [306] long min.
(color coded per schematic)
3/16 x .063
[4,75 x 1,6]
OPTIONS
± 0.1 % Linearity
ELECTRICAL TRAVEL REFERENCE
2.0 (50,8) MLT002N3000B5C
3.0 (76,2) MLT003N4500B5C
4.0 (101,6) MLT004N6000B5C
5.0 (127,0) MLT005N7500B5C
6.0 (152,4) MLT006N9000B5C
± 0.25 % Linearity
ELECTRICAL TRAVEL REFERENCE
1.0 (25,4) MLT001N1500D5C
± 1.0 % Linearity
ELECTRICAL TRAVEL REFERENCE
0.5 (12,7) MLT0R5N0750F5C
1.0 (25,4) MLT001N1500F5C
2.0 (50,8) MLT002N3000F5C
3.0 (76,2) MLT003N4500F5C
4.0 (101,6) MLT004N6000F5C
5.0 (127,0) MLT005N7500F5C
6.0 (152,4) MLT006N9000F5C