Honeywell Switches and Sensors Switch User Manual


 
30
www.honeywell.com/sensing
COMPACT LIMIT SWITCHES
LS Series
Plunger actuated switches
OPTIONS
Top pin plunger
Operating force max. (OF): Standard 31,14 N (7 lb)
Low 10 N (36 oz)
Pretravel max. (PT): 1,65 mm (0.065 in)
Overtravel min. (OT) Standard 6,35 mm (0.25 in)
Low 5,56 mm (0.219 in)
Differential travel max. (DT): Standard 0,51 mm (0.020 in)
Low 0,23 mm (0.009 in)
Switching options: SPDT
CONDUIT ELECTRICAL RATING REFERENCE
A 2LS1
F 2LS1-L
20 mm A 2LS1-4C
Low OF/OT/DT E 2LS111
Top roller plunger
Operating force max. (OF): 31,14 N (7 lb)
Pretravel max. (PT): 1,65 mm (0.065 in)
Overtravel min. (OT) 5,56 mm (0.219 in)
Differential travel max. (DT): 0,51 mm (0.020 in)
Switching options: SPDT
CONDUIT ELECTRICAL RATING REFERENCE
A 5LS1
F 5LS1-L
20 mm A 5LS1-4C
Side pin plunger
Operating force max. (OF): 40,03 N (9 lb)
Pretravel max. (PT): 2,8 mm (0.110 in)
Overtravel min. (OT) 6,35 mm (0.25 in)
Differential travel max. (DT): 1,02 mm (0.040 in)
Switching options: SPDT
CONDUIT ELECTRICAL RATING REFERENCE
A4LS1
20 mm A 4LS1-4C
Side roller plunger
Operating force max. (OF): 40,03 N (9 lb)
Pretravel max. (PT): 2,8 mm (0.110 in)
Overtravel min. (OT) 5,56 mm (0.219 in)
Differential travel max. (DT): 1,02 mm (0.040 in)
Switching options: SPDT
CONDUIT ELECTRICAL RATING REFERENCE
A3LS1
20 mm A 3LS1-4C