Honeywell Switches and Sensors Switch User Manual


 
83
www.honeywell.com/sensing
SAFETY SWITCHES
GK Series
Dual Entry Key
Operated Safety
Interlock Switch
The GK Series is designed specifically for use on machines where key removal brings the machine to an
immediate safe condition. It provides enhanced operator safety when added to hinged or sliding guard
doors, screens and protective covers on enclosures. The GK Series is especially well suited for large door
applications, typically in the automotive plant floor environment. Its heavy duty construction withstands
harsh industrial environments where rugged, long-term durability is required.
Nearly 1000 options are available in a simple to understand part number tree.
A safety lockout device is also available for use with the GK Series. The lockout device (GKZL2) is specifically
designed to prevent a key from being inserted either manually, or by the access door being closed while
maintenance personnel are working on the machine. When inserted, the lockout device can accommodate
up to four padlocks to prevent unauthorised removal of the device.
Mechanical life: up to 15 million
Sealing: IP 67, NEMA/UL type 1, 4, 12,13
Operating temperature: -25 °C to 85 °C (-13 °F to 185 °F)
Approvals: CE, CSA, UL
AC15 A300/A600
DC13 Q300
Contacts: Silver
Low energy Gold
Switching options:
Snap action contacts (1NC/1NO) Snap action contacts (2NC/2NO)
13
21
14
22
Zb
13
14
21
22
11
23
12
24
Slow action contacts (1NC/1NO), BBM Slow action contacts (2NC)
Zb
21
13
22
14
21
11
22
12
2Y
Slow action contacts (2NC/2NO), BBM Slow action contacts (3NC/1NO)
21 22
13 14
23 24
11 12
2y,2x
21 22
31 32
43 44
11 12
3y,1x
Slow action contacts (4NC)
21 22
31 32
41 42
11 12
4y
Electrical ratings:
IEC 60947-5-1/EN 60947-5-1
Designation & Utilization
Rated operational current le (A) VA
Category
at rated operational voltage Ue rating
120 V 240 V 380 V 480 V 500 V 600 V Make Break
AC15 A600 6 3 1,9 1,5 1,4 1,2 7200 720
AC15 A300 6 3 ----7200 720
AC15 B300 3 1.5 ----3600 360
AC14 D300 0,6 0,3 ---- 43272
125 V 250 V
DC13 Q300 0,55 0,27 69 69
DC13 R300 0,22 0,1 28 28