Honeywell Switches and Sensors Switch User Manual


 
131
www.honeywell.com/sensing
PRESSURE SENSORS
10,0 in. (0.375) max
.
PSI: 1/8-27 NPT, 16,0 (0.625) Hex
7/16 UNF, 14,0 (05625) Hex
BAR: G1/4, 19,0 (0.75) Hex
3 Conductor, 24 AWG,
Color Coded, Shielded
Cable, 0,91 m (3 ft.)
(1.875)
48,0 max.
(1.0)
max.
25,0
10,0 (0.375) max.
(1.0) ma
x
25,0
C
Ground
B
Output
A
Excitation
PSI: 1/8-27 NPT, 15,9 (0.625) Hex
BAR: G 16,0 (0.25) Hex
23,0
38,0
25,0 max
25,0
(1.0)
(0.875) (1.5) (1.0)
OPTIONS
To meet the requirements of automotive applications, the Model Eclipse is
offered with the Packard Metri-PackTM electrical connector. This connector
has been specified for the extreme environments found in engine and
hydraulic applications. The connector has a locking lug to maintain the
connection with the mating plug.
Packard - 0.5 Vdc to 4.5 Vdc Output
1/8 in - 27 NPT Connector
MEASUREMENT TYPE PRESSURE RANGE REFERENCE
Sealed Gauge 0 psis to 200 psis EC200PS1PC
Sealed Gauge 0 psis to 300 psis EC300PS1PC
Sealed Gauge 0 psis to 500 psis EC500PS1PC
Sealed Gauge 0 psis to 2,000 psis EC02KPS1PC
Sealed Gauge 0 psis to 3,000 psis EC03KPS1PC
G1/4 in - 19 BSP Connector
MEASUREMENT TYPE PRESSURE RANGE REFERENCE
Sealed Gauge 0 bar to 350 bar EC350BS6PC
4 mA to 20 mA Output
G1/4 in - 19 BSP Connector
MEASUREMENT TYPE PRESSURE RANGE REFERENCE
Gauge 0 bar to 1 bar EC001BG6PG
OPTIONS
The Model Eclipse can be provided with an all stainless steel case and an
integral cable for electrical connection. The advantage of this arrangement is
that the environment rating is increased to IP66 and would be recommended
for extreme outdoor or industrial environments.
Model Cable
MEASUREMENT TYPE PRESSURE RANGE REFERENCE
Sealed Gauge 0 psis to 100 psis EC100PS1CG
Sealed Gauge 0 psis to 5,000 psis EC05KPS1CG
Eclipse Series (continued)