Honeywell Switches and Sensors Switch User Manual


 
133
www.honeywell.com/sensing
PRESSURE SENSORS
SA Series
The harsh duty SA pressure transducer has a water resistant, stainless steel
case for complete protection from harsh environments. Internal hermetic
sealing is used to provide measurement from absolute pressures (psia) or
pressures referenced to a sealed chamber (psis). Underwriters Laboratories
has approved the SA as a component in float and pressure-operated motor
controllers (File #E93356).
Approvals: UL (*C1D products)
CE (*C1DE products)
Supply voltage: 9.0 Vdc to 24.0 Vdc
Signal conditioning: Amplified compensated
Operating temperature range: -55 °C to 105 °C (-48 °F to 221 °F)
Compensated temperature range: -1 °C to 85 °C (30 °F to 185 °F)
Port style: 1/8-27 NPT
Output type: 1 Vdc to 6 Vdc
Termination type: 0,91 m (3 ft) 3-conductor shielded cable
10,0
(0.38)
19,0
(0.75)
48,0
(1.88)
40,0
(1.56)
3 conductor
color coded
shielded cable
0,91 m long (
3 ft)
Excitation: Red
Signal: Wht
Common: Blk
Bare
(case shield)
1/8-27 NPT
3/8-24 UNF (optional 100 PSI)
1/2 Hex for 1/8-27 NPT port
9/16 Hex for 3/8-24 UNF port
SA WITH CABLE
OPTIONS
UL Approval
MEASUREMENT TYPE PRESSURE RANGE REFERENCE
Absolute 0 psia to 15 psia SA015PA1C1D
Absolute 0 psia to 25 psia SA025PA1C1D
Absolute 0 psia to 50 psia SA050PA1C1D
Absolute 0 psia to 100 psia SA100PA1C1D
Gauge 0 psig to 15 psig SA015PG1C1D
Sealed Gauge 0 psis to 100 psis SA100PS1C1D
Sealed Gauge 0 psis to 200 psis SA200PS1C1D
Sealed Gauge 0 psis to 500 psis SA500PS1C1D
Sealed Gauge 0 psis to 3,000 psis SA03KPS1C1D
CE Approval
MEASUREMENT TYPE PRESSURE RANGE REFERENCE
Absolute 0 psia to 25 psia SA025PA1C1DE
Absolute 0 psia to 50 psia SA050PA1C1DE
SR Series
The Model SR is intended for OEMs requiring a small pressure sensor with
high pressure capability and superior corrosion resistance. Constructed of
brazen assembly of 300 series stainless steels, the SR can tolerate a wide
variety of corrosive medial without risk of leaking. The SR’s design provide
high working pressures and high overload and burst pressures at no extra
cost.
Supply voltage: 5.0 Vdc
Signal conditioning: Unamplified compensated
Operating temperature range: -40 °C to 100 °C (-40 °F to 212 °F)
Compensated temperature range: 0 °C to 75 °C (32 °F to 167 °F)
Port style: Capsule
Output type: 0 mV to 100 mV
Termination type: 4 - 22 AWG tinned Cu wires
b
d
A
4, 22 AWG
TINNED Cu SOLID WIRES
14,0
(0.55)
LONG
O-RING GROOVE
(0.625)
15,0 max.
4,3 max.
7,6 max.
19,0 / 18,95
18,5
19,5 max.
(0.766)
(0.75)
(0.748 / 0.746)
c
a
+ Signal
- Signal
- Excitation
+ Excitation
(0.30)
(0.17)
CAUTION: Contact with sensing surface at bottom of cavity will affect
accuracy and may cause damage. The O-ring groove on 2000 psi unit is
wider to accommodate a backup ring behind the O-ring.
All dimensions in inches (mm).
erusserP
egnaR
)ISP(
A*
.aiDeroBgniR-O
gnilaeS
**htpeD
ytivaC
htpeD
005-51
005.
)07.21(
210-2)33.5(12.)85.5(22.
0051-0001 )25.9(573.010-2)33.5(12.)85.5(22.
0002 )25.9(573.010-2)33.5(12.)85.5(22.
PRESSURE RANGE (PSI)
OPTIONS
MEASUREMENT TYPE PRESSURE RANGE REFERENCE
Gauge 0 psig to 15 psig SR015PGTB
Gauge 0 psig to 25 psig SR025PGTB
Gauge 0 psig to 50 psig SR050PGTB
Gauge 0 psig to 100 psig SR100PGTB
Gauge 0 psig to 200 psig SR200PGTB
Gauge 0 psig to 300 psig SR300PGTB
Gauge 0 psig to 500 psig SR500PGTB
Gauge 0 psig to 1,000 psig SR01KPGTB
Gauge 0 psig to 2,000 psig SR02KPGTB