Honeywell Switches and Sensors Switch User Manual


 
128
www.honeywell.com/sensing
PRESSURE SENSORS
AB/HP Series
The AB-High Performance pressure transducer is extremely accurate down to
0.25% span over a wide compensated temperature range. Both zero and full-
scale temperature compensation are held to extremely narrow limits.
The transducer’s body is made in a configuration permitting its use as a ‘flush-
mounted’ device in situations where ease of cleaning or low-fluid volumes are
major requirements. It may also be mounted in an adaptor for more
conventional installations. Made from 316L or 15-5PH stainless steel, the AB/
HP offer premium performance and flexibility at OEM prices.
Approvals: CE
Supply voltage: 5.0 Vdc, 6.0 Vdc max.
Signal conditioning: Unamplified compensation
Compensated temperature range: -1 °C to 71 °C (30 °F to 160 °F)
Port style: Flush Diaphragm
Output type: 0 mV to 100 mV
+ Excitation: Red
+ Signal: Grn
– Excitation: Blk
– Signal: Wht
4 conductor
color coded
shielded cable
0.91 m long
(3 ft. )
Shield
(drain)
23
,
8
max. dia.
(0.935)
19
,
0 max. dia.
(0.749)
A
Pressure sensitive surface
(diaphragm)
29
,
2
max.
(1.15)
6
,
4
(0.25)
OPTIONS
0,91 m (3 ft) 4-Conductor Shielded Cable
-54 °C to 93 °C (-65 °F to 200 °F)
MEASUREMENT TYPE PRESSURE RANGE REFERENCE
Absolute 0 psia to 15 psia ABH015PAC1B
Absolute 0 psia to 50 psia ABH050PAC1B
Gauge 0 psig to 6 psig ABH006PGC1B
Gauge 0 psig to 25 psig ABH025PGC1B
Gauge 0 psig to 15 psig ABH015PGC1B
Sealed Gauge 0 psis to 100 psis ABH100PSC1B
Sealed Gauge 0 psis to 200 psis ABH200PSC1B
Sealed Gauge 0 psis to 500 psis ABH500PSC1B
Sealed Gauge 0 psis to 1,000 psis ABH01KPSC1B
Sealed Gauge 0 psis to 2,000 psis ABH02KPSC1B
Sealed Gauge 0 psis to 3,000 psis ABH03KPSC1B
Bendix High Temperature Connector
-54 °C to 149 °C (-65 °F to 300 °F)
MEASUREMENT TYPE PRESSURE RANGE REFERENCE
Absolute 0 psia to 25 psia ABH025PABB
Sealed Gauge 0 psis to 3,000 psis ABH03KPSBB
Sealed Gauge 0 psis to 10,000 psis ABH10KPSBB
BL Series
The BL pressure transmitter has a conventional 4 mA to 20 mA output and is
available with accuracies to 0.25%. It has Factory Mutual approval as an
intrinsically safe device for use in hazardous areas. Class I, Division I, Groups
A through G (when used within approved barriers).
Approvals: CE, FM
Supply voltage: 12.0 Vdc to 30.0 Vdc
Signal conditioning: Amplified compensated
Operating temperature range: -40 °C to 82 °C (-40 °F to 180 °F)
Compensated temperature range: -1 °C to 54 °C (-30 °F to 130 °F)
Port style: Flush Diaphragm
Output type: 4 mA to 20 mA
Termination type: Bendix Connector
A
B
C
D
E
F
CONNECTOR
PTIH-10-6P
20,6
79,0 max.
A
B
19,05 max.
(0.75)
23,75 max.
(0.875)
(3.125)
(0.75)
PRESSURE
SENSITIVE
DIAPHRAGM
A
B
C & D
E
+ EXCITATION
RETURN
ZERO BALANCE
CASE GROUND
OPTIONS
MEASUREMENT TYPE PRESSURE RANGE REFERENCE
Gauge 0 psig to 15 psig BLH015PGBG
Gauge 0 psig to 15 psig BL015PGBG
Sealed Gauge 0 psis to 100 psis BL100PSBG
Sealed Gauge 0 psis to 100 psis BLH100PSBG
Sealed Gauge 0 psis to 200 psis BL200PSBG
Sealed Gauge 0 psis to 500 psis BL500PSBG
Sealed Gauge 0 psis to 5,000 psis BL05KPSBG
Sealed Gauge 0 psis to 10,000 psis BLH10KPSBG
PRESSURE RANGE (PSI)
)ISP(egnaRerusserPXAMA.miDB.miD
5-0172.)9.6(52.)4.6(
05-0ot51-1232.)9.5(52.)4.6(
002-0ot001-0832.)1.6(52.)4.6(
0001-0ot005-0832.)1.6(91.)8.4(
0005-0ot0002-0372.)9.6(91.)8.4(
00051-0ot00001-0782.)3.7(91.)8.4(
00002-0582.)5.7(91.)8.4(