Honeywell Switches and Sensors Switch User Manual


 
29
www.honeywell.com/sensing
No lever
Note: Levers are ordered separately (see pages 69-71
for details)
Operating force max. (OF): Standard 0,51 N m (4.5 in lb)
Low with standard PT 0,21 N m (30 in oz)
Low with low PT 0,11 N m (1 in lb)
Pretravel max. (PT): Standard 20°
Low
Maintained contact 55°
Overtravel min. (OT) Standard 30°
Maintained contact 35°
Differential travel max. (DT): Standard 12°
Low PT
Maintained contact 20°
Switching options: SPDT
Maintained contact
SPDT contact
CONDUIT ELECTRICAL RATING REFERENCE
A 1LS2
F 1LS2-L
20 mm A 1LS2-4C
Low OF A 1LS23
Low OF/PT B 1LS56
Low PT B 1LS9
Maintained contact
CONDUIT ELECTRICAL RATING REFERENCE
A 6LS2
F 6LS2-L
Adjustable rod
Operating force max. (OF): Standard 1,39 N (5 oz)
Low 0,83 Nm (3 oz)
Pretravel max. (PT): Standard 20°
Low
Overtravel min. (OT) 30°
Differential travel max. (DT): Standard 12°
Low
Switching options: SPDT
Lever: Aluminium rod
CONDUIT ELECTRICAL RATING REFERENCE
A 1LS10
F 1LS10-L
20 mm A 1LS10-4C
Low PT B 1LS47
Low PT/OF/DT B 1LS53
Side rotary, yoke lever, maintained contact
Operating force max. (OF): 8,9 N (2.0 lb)
Pretravel max. (PT): 55°
Switching options: Maintained
Lever: 6LS1 Steel rollers on opposite sides of arm
6LS3 Nylon rollers on same side of arm
CONDUIT ELECTRICAL RATING REFERENCE
A 6LS1
20 mm A 6LS1-4C
A 6LS3
COMPACT LIMIT SWITCHES