IBM 9308 Personal Computer User Manual


 
The NetBAY Console Cable Set is available separately to connect servers to your
console switch. The console cables are available in different lengths, and are
color-coded in the same manner as the ports on the console switch.
The locking keyboard and mouse connectors automatically lock when you connect
them to prevent accidental disconnection. To disconnect one of these cables, grasp
the color-coded housing on the connector; then, pull the housing away from the
console switch to unlock the connector and disconnect the cable.
Cable
Locking
housing
Connector
Tool requirements
You will need the following tools to install the console switch:
v A Phillips screwdriver
v A 10mm nut driver or 10mm open-end or box wrench
Specifications
The following table contains the product specifications for the 1x4 Console Switch
and the 2x8 Console Switch:
1x4 Console Switch 2x8 Console Switch
Height 4.3 cm (1.7 in.) 4.3 cm (1.7 in.)
Depth 20.3 cm (8.0 in.) 20.3 cm (8.0 in.)
Width 43.2 cm (17 in.) 43.2 cm (17 in.)
Weight 2.38 kg (5.25 lbs) 2.59 kg (5.7 lbs)
Rated voltage 100 240 V ac 100 240 V ac
Rated frequency 50 60 Hz 50 60 Hz
Rated input current 1.0 A maximum 1.0 A maximum
Operating temperature at 0914
m (03000 ft)
10° 35°C (50° 95°F) 10° 35°C (50° 95°F)
Operating temperature at
914-2133 m (3000-7000 ft)
10° 32°C (50° 90°F) 10° 32°C (50° 90°F)
Operating humidity
(non-condensing)
8% 80% 8% 80%
Video modes supported VGA, SVGA, XGA VGA, SVGA, XGA
124 Hardware Maintenance Manual: IBM PC Server/Enterprise Racks Types 9306, 9308