IBM DS8000 Server User Manual


 
Action
Correct the port specification, and then resubmit the task. If the problem persists,
contact IBM technical support for assistance.
CMUN02070E SOURCE Unable to create SCSI host port: invalid WWPN
Explanation
The worldwide port name is invalid. A WWPN must be a 16-character hexadecimal
string.
Action
Provide a valid worldwide port name, and then resubmit the task. If the problem
persists, contact IBM technical support for assistance.
CMUN02071E SOURCE Unable to create SCSI host port: invalid WWPN
Explanation
The worldwide port name is invalid. A WWPN must be a 16-character hexadecimal
string.
Action
Provide a valid worldwide port name, and then resubmit the task. If the problem
persists, contact IBM technical support for assistance.
CMUN02072E SOURCE Unable to create SCSI host port: invalid
override default priority
Explanation
The attribute value that indicates whether default priority for I/O operations can be
overridden is invalid.
Action
Correct the port specification, and then resubmit the task. If the problem persists,
contact IBM technical support for assistance.
CMUN02073E SOURCE Unable to create volume group
Explanation
The storage management console server reports a storage unit microcode-level
error.
Action
Contact IBM technical support for assistance.
166 IBM TotalStorage DS8000: Messages Reference