IBM DS8000 Server User Manual


 
CMUC00169I COMMAND_INFO FlashCopy volume pair PAIR_ID successfully
reversed.
Explanation
The original FlashCopy source volume has been made the target volume. The
original FlashCopy target volume has been made the source volume. Any
uncommitted incremental changes to the original source volume data have been
overwritten with older data from the new source volume.
Action
None.
CMUC00170I COMMAND_INFO FlashCopy volume pair PAIR_ID successfully
committed.
Explanation
Changes to the FlashCopy source volume data have been committed to the target
volume.
Action
None.
CMUC00171I COMMAND_INFO FlashCopy volume pair PAIR_ID successfully
reverted.
Explanation
All new writes to the source volume since the last time source data was committed
to the target volume have been discarded.
Action
None.
CMUC00172I COMMAND_INFO FlashCopy consistency group for logical
subsystem PAIR_ID successfully reset.
Explanation
A mkflash -freeze or resyncflash -freeze command has been invoked previously
against this consistency group. The unfreezeflash command successfully reset the
consistency group.
Action
None.
52 IBM TotalStorage DS8000: Messages Reference