CMUN03066E SOURCE Copy Services operation failure: no volume zero
on secondary logical subsystem
Explanation
The storage management console server reports a Copy Services error.
Action
Contact IBM technical support for assistance.
CMUN03067E SOURCE Copy Services operation failure: configuration
does not exist
Explanation
The specified configuration does not exist or the specified logical subsystem is
incorrect.
Action
Ensure that the correct pair and the correct logical subsystem are specified, and
then resubmit the task.
CMUN03068E SOURCE Copy Services operation failure: not ready for
resync
Explanation
Both the source and target volumes must be suspended before they can be
resynchronized.
Action
Suspend the volumes, and then resubmit the task.
CMUN03069E SOURCE Pair capacity mismatch
Explanation
The capacity of a target volume must be greater than or equal to the size of the
source volume. The target volume is too small.
Action
Specify a target volume that is larger than or equal to the size of the source
volume, and then resubmit the task.
CMUN03070E SOURCE Copy Services operation failure: pairs remain
Explanation
The path cannot be removed because Remote Mirror and Copy pairs are currently
using the path.