IBM S544-5285-01 Printer User Manual


 
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
APK171S DATA IN AN INPUT RECORD OR
RESOURCE IS INVALID: FONT LOCAL
IDENTIFIER VALUE IS NOT
ACCEPTABLE IN THE
structured field
STRUCTURED FIELD.
Explanation: The Map Coded Font (MCF) structured
field consists of repeating groups. In one of the groups,
the value of the Coded Font Local Identifier parameter
for the font (section) being mapped is invalid. The MCF
structured field is contained in a composed-text print
data set, an overlay, or a page definition.
System Action: ACIF stops processing the print data
set. ACIF issues a message identifying the position of
the structured field in the data stream or resource.
User Response: If you created the structured fields
for the print data set or the resource, correct the error
and resubmit the print request. Refer to
Mixed Object
Document Content Architecture Reference
or
Advanced
Function Presentation: Programming Guide and Line
Data Reference
for more information about the
structured field. If the structured field has no error, the
error may be an ACIF logic error. If you used a program
to create the structured fields for the print data set or
the resource, contact your system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
print data set or the resource with the error, verify that
the input to that program was valid. If the input was
valid, refer to
Advanced Function Printing: Diagnosis
Guide
for assistance in determining the source of the
problem.
APK172S DATA IN A FORMDEF RESOURCE IS
INVALID: THE SET OF MODIFICATIONS
SPECIFIED IN THE MCC STRUCTURED
FIELD INCLUDES BOTH NORMAL AND
TUMBLE DUPLEX.
Explanation: The Medium Copy Count (MCC)
structured field refers to one or more Medium
Modification Control (MMC) structured fields , which
include requests for both normal duplex and tumble
duplex. You cannot request both normal duplex and
tumble duplex within the same medium map. The MCC
and MMC structured fields are contained in the form
definition.
System Action: ACIF stops processing the print data
set. ACIF issues a message identifying the position of
the structured field in the data stream or resource.
User Response: If you created the structured fields
for the form definition, correct the MCC or MMC
structured field. Refer to
Mixed Object Document
Content Architecture Reference
for more information
about the structured field. If the MCC and MMC have
no errors, the error may be an ACIF logic error. If you
used a program to create the structured fields for the
form definition, contact your system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
form definition with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
APK178S DATA IN A FORMDEF RESOURCE IS
INVALID: THE MCC STRUCTURED FIELD
HAS AN ODD NUMBER OF COPY
GROUPS, BUT SPECIFIES DUPLEX.
Explanation: The Medium Copy Count (MCC)
structured field specifies an odd number of copy groups,
but the copy group modifications specified in the
Medium Modification Control (MMC) structured field
include duplex, which requires an even number of copy
groups. The MCC and MMC structured fields are
contained in the form definition.
System Action: ACIF stops processing the print data
set. ACIF issues a message identifying the position of
the structured field in the data stream or resource.
User Response: If you created the structured fields
for the form definition, correct the MCC or MMC
structured field. Refer to
Mixed Object Document
Content Architecture Reference
for more information
about the structured field. If the MCC and MMC have
no errors, the error may be an ACIF logic error. If you
used a program to create the structured fields for the
form definition, contact your system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
form definition with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
APK179S DATA IN A FORMDEF RESOURCE IS
INVALID: THE SET OF MODIFICATIONS
SPECIFIED IN THE MCC STRUCTURED
FIELD INCLUDES BOTH SIMPLEX AND
DUPLEX.
Explanation: The Medium Copy Count (MCC)
structured field refers to two or more Medium
Modification Control (MMC) structured fields , which
include requests for both simplex and duplex printing.
You cannot specify both simplex and duplex printing
within the same medium map. The MCC and MMC
structured fields are contained in the form definition.
System Action: ACIF stops processing the print data
set. ACIF issues a message identifying the position of
the structured field in the data stream or resource.
Chapter 10. ACIF Messages for OS/390, MVS, VM, and VSE 145