User Response: If you created the structured fields
for the form definition, correct the MCC or MMC
structured field. Refer to
Mixed Object Document
Content Architecture Reference
for more information
about the structured field. If the MCC and MMC have
no errors, the error may be an ACIF logic error. If you
used a program to create the structured fields for the
form definition, contact your system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
form definition with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
APK181S DATA IN A FORMDEF RESOURCE IS
INVALID: UNEQUAL COPY COUNTS
FOR DUPLEX SHEETS ARE SPECIFIED
IN THE MCC STRUCTURED FIELD.
Explanation: The set of modifications referred to by
the Medium Copy Count (MCC) structured field includes
duplexing, but the numbers of copies in two
corresponding repeating groups are not equal. The
repeating groups are defined in the Medium Map
Control structured field (MMC). The MCC and MMC
structured fields are contained in the form definition.
System Action: ACIF stops processing the print data
set. ACIF issues a message identifying the position of
the structured field in the data stream or resource.
User Response: If you created the structured fields
for the form definition, correct the MCC or MMC
structured field. Refer to
Mixed Object Document
Content Architecture Reference
for more information
about the structured field. If the MCC and MMC have
no errors, the error may be an ACIF logic error. If you
used a program to create the structured fields for the
form definition, contact your system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
form definition with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
APK188S DATA IN A FORMDEF RESOURCE IS
INVALID: THE SET OF MODIFICATIONS
SPECIFIED IN THE MCC STRUCTURED
FIELD SELECTS MORE THAN ONE
INPUT SOURCE.
Explanation: The Medium Copy Count (MCC)
structured field refers to one or more Medium
Modification Control (MMC) structured fields , which
include requests for the primary input source and the
alternate source. You cannot specify both the primary
input source and the alternate source for one copy
group. The MCC and MMC structured fields are
contained in the form definition.
System Action: ACIF stops processing the print data
set. ACIF issues a message identifying the position of
the structured field in the data stream or resource.
User Response: If you created the structured fields
for the form definition, correct the MCC or MMC
structured field. Refer to
Mixed Object Document
Content Architecture Reference
for more information
about the structured field. If the MCC and MMC have
no errors, the error may be an ACIF logic error. If you
used a program to create the structured fields for the
form definition, contact your system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
form definition with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
APK190S DATA IN A FORMDEF RESOURCE IS
INVALID: THE BIN-SELECTION VALUE
IN MMC STRUCTURED FIELD, ID
identifier
, IS NOT ACCEPTABLE.
Explanation: In the Medium Modification Control
(MMC) structured field with the identifier specified in the
message text, the bin-selection parameter value was
invalid. The MMC structured field is contained in the
form definition.
System Action: ACIF stops processing the print data
set. ACIF issues a message identifying the position of
the structured field in the data stream or resource.
User Response: If you created the structured fields
for the form definition, correct the MMC structured field
and resubmit the print request. Refer to
Mixed Object
Document Content Architecture Reference
for more
information about the structured field. If the MMC has
no errors, the error may be an ACIF logic error. If you
used a program to create the structured fields for the
form definition, contact your system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
form definition with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
146 ACIF User’s Guide