IBM S544-5285-01 Printer User Manual


 
APK465S INVALID TOKEN '
token
' RECEIVED
Explanation: The token identified in the message was
not expected in the parameter listed above the
message.
System Action: ACIF continues processing the
parameter file, but does not process the report file.
User Response: Correct the value of the parameter
and rerun ACIF.
APK466S A SUB-PARAMETER OF '
sub-parameter
'
IS NOT SUPPORTED OF THE '
parameter
'
PARAMETER.
Explanation: The named sub-parameter is not
supported on the parameter listed above the message.
System Action: ACIF continues processing the
parameter file, but does not process the report file.
User Response: Correct the value of the parameter
and rerun ACIF.
APK467S THE NUMBER '
number
' IS NOT
SUPPORTED FOR {FIELD | INDEX |
TRIGGER}.
Explanation: An invalid number was specified on a
FIELD, INDEX, or TRIGGER parameter keyword.
System Action: ACIF continues processing the
parameter file, but does not process the report file.
User Response: Correct the parameter keyword so
that the number is within the allowed range for that
parameter and rerun ACIF.
APK468S THE INPUT BUFFER IS TOO SMALL FOR
THE PARAMETER VALUE
'
value
'.
Explanation: The named value was too long for the
ACIF internal input buffer.
System Action: ACIF terminates.
User Response: Use your local problem reporting
system to report the error.
APK469S THE LENGTH OF THE VALUE '
value
'
EXCEEDS THE MAXIMUM ALLOWED
LENGTH FOR THE
parameter
PARAMETER.
Explanation: The length of the named value exceeds
the maximum length.
System Action: ACIF continues processing the
parameter file, but does not process the report file.
User Response: Correct the value so that its length is
within the maximum for that parameter and rerun ACIF.
APK470S WHICH BEGINS AT OFFSET
offset
FOR A
LENGTH OF
length
.
Explanation: The message is issued following a
message which contains the cause of the error.
System Action: See the preceding message.
User Response: See the preceding message.
APK471S THE NUMBER OF FIELD VALUES ON
THE INDEX PARAMETER EXCEEDED
THE MAXIMUM ALLOWED.
Explanation: There were too many FIELDnn values
specified for the INDEX parameter printed above this
message.
System Action: ACIF continues processing the
parameter file, but does not process the report file.
User Response: Remove the extra FIELDnn values
from the INDEX parameter and rerun ACIF.
APK472S THE NUMBER OF VALUES SPECIFIED
FOR THE
parameter
PARAMETER
EXCEEDED THE MAXIMUM ALLOWED.
Explanation: Too many values were specified for the
named parameter.
System Action: ACIF continues processing the
parameter file, but does not process the report file.
User Response: Consult the ACIF manual for the
maximum number of values for this parameter, correct
the parameter, and rerun ACIF.
APK474S END-OF-FILE ENCOUNTERED BEFORE
CLOSING QUOTE FOUND FOR
'
value
'.
Explanation: The end of the parameter file was found
before the closing quote for a literal value.
System Action: ACIF terminates.
User Response: Ensure the literal value is enclosed
in quotes and rerun ACIF.
APK475S THE HEX STRING '
hex string
' IS NOT
VALID.
Explanation: The value specified was not a valid hex
string.
System Action: ACIF continues processing the
parameter file, but does not process the report file.
User Response: Correct the hex string and rerun
ACIF.
Chapter 10. ACIF Messages for OS/390, MVS, VM, and VSE 171