IBM S544-5285-01 Printer User Manual


 
APK309S DATA IN A PAGEDEF RESOURCE IS
INVALID: THE REPEATING GROUP
LENGTH PARAMETER VALUE IN CCP
STRUCTURED FIELD
CCP identifier
IS
INVALID.
Explanation: The Conditional Processing Control
(CCP) structured field has an invalid value. Either the
Length of Repeating Groups parameter is zero, or the
length of the repeating group data is not a multiple of
the size specified in that parameter. The CCP
structured field is contained in the page definition.
System Action: ACIF stops processing the print data
set, and issues a message identifying the position of the
structured field in the data stream or resource.
User Response: If you created the structured fields
for the page definition, correct the error and resubmit
the print request. Refer to
Advanced Function
Presentation: Programming Guide and Line Data
Reference
for more information about the structured
field. If the structured field has no error, the error may
be an ACIF logic error. If you used a program to create
the structured fields for the page definition, contact your
system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
page definition with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
APK310S DATA IN A PAGEDEF RESOURCE IS
INVALID: THE COUNT PARAMETER
VALUE IN THE LNC STRUCTURED FIELD
WAS 0.
Explanation: The Count parameter in the Line
Descriptor Count (LNC) structured field had a value of
zero. The LNC structured field is contained in the page
definition.
System Action: ACIF stops processing the print data
set and issues a message identifying the position of the
structured field in the data stream or resource.
User Response: If you created the structured fields
for the page definition, correct the error and resubmit
the print request. Refer to
Advanced Function
Presentation: Programming Guide and Line Data
Reference
for more information about the structured
field. If the structured field has no error, the error may
be an ACIF logic error. If you used a program to create
the structured fields for the page definition, contact your
system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
page definition with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
APK312S DATA IN A PAGEDEF RESOURCE IS
INVALID: THE SIZE PARAMETER VALUE
IN THE FDS STRUCTURED FIELD WAS 0.
Explanation: The Size parameter in the Fixed Data
Size (FDS) structured field has a value of 0. The FDS
structured field is contained in the page definition.
System Action: ACIF stops processing the print data
set, and issues a message identifying the position of the
structured field in the data stream or resource.
User Response: If you created the structured fields
for the page definition, correct the error and resubmit
the print request. Refer to
Advanced Function
Presentation: Programming Guide and Line Data
Reference
for more information about the structured
field. If the structured field has no error, the error may
be an ACIF logic error. If you used a program to create
the structured fields for the page definition, contact your
system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
page definition with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
APK314S DATA IN A PAGEDEF RESOURCE IS
INVALID: THE NUMBER OF REPEATING
GROUPS PARAMETER VALUE IN CCP
STRUCTURED FIELD
CCP identifier
IS
INVALID.
Explanation: The Conditional Processing Control
(CCP) structured field has an invalid value. Either the
Number of Repeating Groups parameter contained in
the CCP structured field is zero, or the number of
repeating groups does not match the number specified
in the parameter. The CCP structured field is contained
in the page definition.
System Action: ACIF stops processing the print data
set, and issues a message identifying the position of the
structured field in the data stream or resource.
User Response: If you created the structured fields
for the page definition, correct the error and resubmit
the print request. Refer to
Advanced Function
Presentation: Programming Guide and Line Data
Reference
for more information about the structured
field. If the structured field has no error, the error may
be an ACIF logic error. If you used a program to create
the structured fields for the page definition, contact your
system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
page definition with the error, verify that the input to that
156 ACIF User’s Guide