IBM Partner Pavilion T400 Switch User Manual


 
Fixing Fibre Channel Errors
If you are connected to a Fibre Channel Storage Area Network (SAN) by using a
SAN Data Gateway, use the IBM Storage Area Network Gateway Module Setup,
Operator, and Service Guide to determine whether the problem is occurring
between the drive and the SAN Data Gateway. If you are using a SCSI drive and
are having SCSI problems, see Fixing SCSI Bus Errorson page 77.
Starting Problem Determination
Before starting the problem determination, perform the following steps:
1. Determine the type of Fibre Channel topology that you are using (see page 6).
Ensure that the drive and the port to which it is attached are configured in
compatible topologies.
2. Using this guide or the service guides of associated switch, hub, or fiber
products, try to determine where the problem exists (whether in the drive, cable,
or the device to which the drive and cable attach).
3. Ensure that the configuration and software levels are supported (see Fibre
Channel Attachmenton page 6).
4. Ensure that the Fibre Channel cables are installed correctly. Refer to the
appropriate steps in Chapter 3, Installing the Tape Driveon page 13.
5. Go to one of the following procedures:
v Fixing a Consistent Error with a Single Drive on a Fibre Channel Loop
v Fixing a Consistent Error with Multiple Drives on a Fibre Channel Loopon
page 80
v Fixing a Consistent Error in a Point-to-Point Topologyon page 80
v Fixing Intermittent Fibre Channel Errorson page 81
Fixing a Consistent Error with a Single Drive on a Fibre Channel
Loop
1. Ensure that the tape drive is powered on.
2. Verify that the tape drives serial number is the same as the drive serial number
that the server program is using.
3. Ensure that the drives Fibre Channel AL_PA is set correctly, that it is on the
loop, and that it is not being used by another device (see Setting the Arbitrated
Loop Physical Address (Fibre Channel Drive Only)on page 19). The tape drive
must be able to detect light and communicate with the server.
4. Run the Fibre Channel wrap test at the drives Fibre Channel connector (see
Function Code 6 in Table 9 on page 36).
v If the test fails, replace the tape drive.
v If the test is successful, go to step 5.
5. Run the Fibre Channel wrap test at the end of the fiber cable (see Function
Code 6 in Table 9 on page 36).
v If the test fails, replace the fiber cable.
v If the test is successful, go to step 6.
6. Check the Fibre Channel cable connection at the server.
7. Using a device driver utility such as ntutil or tapeutil, verify that the drive is
properly configured and available at the server.
8. If the problem persists, the fault may be with the servers hardware or software.
Refer to your servers service manual.
Chapter 6. Resolving Problems 79