ICP DAS USA I-7540D Network Card User Manual


 
4.1 tIIILDD…<CR>
Description: Send or receive a standard CAN data frame.
¾ Syntax: tIIILDD…<CR>
t Represent a standard (2.0A) data frame.
III 11 bits Identifier (000~7FF)
L Data length (0~8)
DD… Input data frame value according to the data length
(00~FF)
¾ Response:
Valid command: No response
Invalid command: ?<Error Code><CR>
¾ Note:
It is necessary to enable the “Error Response” function in the i-7540D
Utility, in order to receive Syntax and/or communication error information
at the host PC.
¾ Example:
Command: t03F6112233445566<CR>
Send a CAN message with a standard data frame. ID=03F, DLC=6,
data1=11, data2=22, data3=33, data4=44, data5=55 and data6=66
Note: This command can only be accepted by 7540D’s port 10003
i-7540D CAN-Ethernet Gateway User’s Manual (Version 1.4, April/2008)
59