ICP DAS USA I-7540D Network Card User Manual


 
4.13 99$P0205BBDSP
Description: Change the RS-485 configuration of the i-7540D
¾ Syntax: 99$P0205BBDSP
99$P0105 Command character
BB RS-485 Baud rate
D Data bit
0 = 7 bits data formation
1 = 8 bits data formation
S Stop bit
0 = 1 stop bit
1 = 2 stop bits
P Parity bits
0 = None
1 = Even
2 = Odd
RS-485Baud rate list
BB Description
00 110 bps baud rate of RS-485
01 150 bps baud rate of RS-485
02 300 bps baud rate of RS-485
03 600 bps baud rate of RS-485
04 1200 bps baud rate of RS-485
05 2400 bps baud rate of RS-485
06 4800 bps baud rate of RS-485
07 9600 bps baud rate of RS-485
08 19200 bps baud rate of RS-485
09 38400 bps baud rate of RS-485
0A 57600 bps baud rate of RS-485
0B 115200 bps baud rate of RS-485
¾ Response:
Valid Command: OK
Invalid command: ERROR
i-7540D CAN-Ethernet Gateway User’s Manual (Version 1.4, April/2008)