IMC Networks iMcV-Giga-FiberLinX-II Network Card User Manual


 
6
III - Hardware Configuration
Before installing the module in a chassis, there are two features that must be selected
using the DIP switches. These selections are:
Enable or disable management on each port
(DIP switches 1, 2, and 3)
Configure the module as a standalone, a host, or a remote
(DIP switches 7 and 8)
DIP Switch Settings
Before installing the iMcV-Giga-FiberLinX-II, use the DIP switches to set the
hardware-configurable features. The DIP switches are located on switch SW1 on the
iMcV-Giga-FiberLinX-II card. Refer to the diagram and table for switch settings and
available features.
Switch Function Default Setting
1
Management on EXT MGMT port ON
2
Management on DATA port
OFF
3
Management on OPTICS or
UPLINK port
OFF
4
Factory use - Do not change
---
5
Factory use - Do not change
---
6
Factory use - Do not change
---
7
Remote Module OFF
8
Host Module OFF
9
Factory use - Do not change
---
0
Factory use - Do not change
---
Host/Remote and Standalone Units
The iMcV-Giga-FiberLinX-II can be used as a Host, Remote, or Standalone unit.
Refer to the
Application Examples
section for examples.
When two iMcV-Giga-FiberLinX-II units are used as a pair, configure one as a Host
unit (DIP switch 8 = ON) and the other as a Remote unit (DIP switch 7 = ON). As a
host unit, the iMcV-Giga-FiberLinX-II requests management information from the
attached remote unit. It then displays that information, along with its own, when