IMC Networks iMcV-Giga-FiberLinX-II Network Card User Manual


 
35
Enter the extra tag
VLAN ID
(for example, 8) and the Priority (optional). These
values must be identical on both iMcV-Giga-FiberLinX-II modules.
The Data Tag is [8 ]
Data Priority is [0 ]
Are Extra Tags left on the Data Port? [ N ]
4.
On the Host iMcV-Giga-FiberLinX-II module, enter
Y
in the
Are Extra Tags
left on the Data Port?
field to accept only the Extra Tag VLAN ID on the
DATA port. On the Remote iMcV-Giga-FiberLinX-II module, enter
N
to have
the Extra Tag VLAN ID added to incoming and removed from outgoing data on
the DATA port.
5.
Press
S
or
F3
to save the settings.
6.
Type
reboot
. Repeat steps for second module.
Now the iMcV-Giga-FiberLinX-II Host/Remote pair are configured to pass only VLAN
ID 8 data from the Host iMcV-Giga-FiberLinX-II to the Remote iMcV-Giga-FiberLinX-
II. VLAN ID 8 tag is removed before sending the data out of the Remote DATA port.
The Extra Tag VLAN ID 8 is added to all data received on the Remote DATA port
before being sent to the Host iMcV-Giga-FiberLinX-II where the VLAN ID 8 tag
remains on the data leaving the Host DATA port.
HOST DATA: REMOTE DATA:
Untagged Untagged
and Tagged Data and Tagged Data
wrapped in Extra
Tag of VLAN ID=8
Host DIP switch
(8) set to ON
Host DIP switch
(7) set to ON
Management is provided through the chassis only.