IMC Networks iMcV-Giga-FiberLinX-II Network Card User Manual


 
26
Configuration screen, press the space bar, type
unit
, and press
Enter
to open the Unit
Control Settings screen. In this screen you can view the unit FlowControl,
FiberAlert/LinkLoss, Loopback, Maximum Frame Size, and 802.1p Base Priority
(logging-in as a User in a Telnet session allows you to view these settings but prevents
you from changing the settings).
------------------------- Unit Control Settings
-
----------------------------
nit FlowControl Disable FlowControl Globally U
nit FiberAlert TXLinkLoss Plus FXLinkLoss Enabled U
nit LoopBack No LoopBack, Normal Traffic Mode U
nit Max FrameSize 1526 U
02.1p Base Pri Base Priority 4 8
oot Trap Deplay, Seconds 0 B
B ange Value. Use Arrow Keys To Move Cursor. Press Space ar To Ch
Press RETURN To Set New Value. T
yp
e
Q
or
F
4 to Exit.
Unit FlowControl
–This allows you to enable/disable Flow Control functionality on
the unit. You must enable this to use Flow Control on any port. The settings include
the following:
Disable FlowControl Globally
Enable FlowControl If Port Allows
Unit FiberAlert
–This allows you to enable/disable FiberAlert and LinkLoss
functionality on the unit. The settings include:
No FiberAlert Or LinkLoss Enabled
FXLinkLoss Only, Enabled
TXLinkLoss Only, Enabled
FiberAlert Plus FXLinkLoss Enabled
FiberAlert Plus TXLinkLoss Enabled
TXLinkLoss Plus FXLinkLoss Enabled
TXLinkLoss + FXLinkLoss + FiberAlert Enabled
FiberAlert Only
Unit LoopBack
–enable/disable Loopback functionality on the unit. The settings
include the following:
No LoopBack, Normal Traffic Mode
LoopBack Enabled
LoopBack, Src/Dest Address Swap
LoopBack, Address Swap, Clear Multicast bit
No Learning on OPTICS (or UPLINK) or DATA Ports