Intel Desktop Board D925XCV/D925XBC Technical Product Specification
2.9 Jumper Block
CAUTION
Do not move the jumper with the power on. Always turn off the power and unplug the power cord
from the computer before changing a jumper setting. Otherwise, the board could be damaged.
Figure 26 shows the location of the jumper block. The 3-pin jumper block determines the BIOS
Setup program’s mode. Table 36 describes the jumper settings for the three modes: normal,
configure, and recovery. When the jumper is set to configure mode and the computer is powered-
up, the BIOS compares the processor version and the microcode version in the BIOS and reports if
the two match.
OM16682
31
J6J3
Figure 26. Location of the Jumper Block
Table 36. BIOS Setup Configuration Jumper Settings
Function/Mode Jumper Setting Configuration
Normal
1-2
1
3
The BIOS uses current configuration information and
passwords for booting.
Configure
2-3
13
After the POST runs, Setup runs automatically. The
maintenance menu is displayed.
Recovery
None
13
The BIOS attempts to recover the BIOS configuration. A
recovery diskette is required.
80