User Manual version 2.1
OPEN (660) 120/140/150
9-148
G-1-4: ENVIRONMENTAL SPECIFICATIONS
² Operating temperature
0
o
C to 50
o
C
² Storage temperature
-20
o
C to 70
o
C
² Humidity
10% to 90% non-condensing
G-1-5: INTERNATIONAL STANDARD
² Safety standards
Designed to meet the following standards
UL 1950
CSA 22.2 no. 234
VDE EN 60 950
² EMI standards
Designed to meet the following limits
FCC docket 20780 curve “B”
EN55022 “B”
² CE standards
Designed to meet the following standards
IEC-801-2 level 3 8KV air discharge
IEC-801-3 level 3 3V/M
IEC-801-4 level 3 2KV
IEC-801-5 level 3 2KV
G-1-6: MECHANICAL SPECIFICATION
² DC output pin assignment
Pin# Signal Pin# Signal
1 +5V 6 GND
2 +5V 7 GND
3 +5V 8 +12V
4 GND 9 +12V
5 GND
² Dimension (unit: mm)
133.5 x 83.8 x 38.0 (L x W x H)