Intermec 6110 Personal Computer User Manual


 
APPENDIX B PEN*KEY
R
Utilities Program
6110 Hand-Held Computer Users Guide B-15
These error codes apply when COMM SETTINGS is set to
NRINET:
0 No error
6 User aborted communications by pressing
[ESC] key.
800 PC TCP/IP kernel is missing.
801 Invalid client IP address. Make sure the entry
for CLIENT IP ADDRESS is correct, or make
sure the DHCP server is running.
802 Invalid Service or Service Type, or invalid port
number.
803 Invalid host name or IP Address. Make sure
the entry for SERVER NAME is correct, and
that the server is running.
804 Could not create socket. Check all cables and
network connections.
806 Block sent was incomplete or block received
was incomplete.
807 Client and server negotiation failed.
808 Server specified an unsupported block size.
809 Invalid buffer pointer.
810 All server connections are already in use. Try
again later.
811 Timeout while sending data. Connection to
remote machine dropped. Make sure the host
is still running, and check all cables and
network connections.
812 Timeout while receiving data. Connection to
remote machine dropped. Make sure the host
is still running, and check all cables and
network connections.
813 An attempt to send data to the server failed
due to a closed connection. Ensure the server
is still running, check all cables and network
connections.
814 An attempt to receive data from the server
failed due to a closed connection. Ensure the