JVC VN-E4 Network Card User Manual


 
34
Settings (continued)
5-11 Time Page
This page is for setting time.
This page can be used upon access via admin.
Press the AOKB button to enable the new settings upon changing. If the AOKB button is pressed upon entering an invalid value, a
warning message will appear and entry will be denied. Press the ACancelB button to restore the invalid entry to the current value.
A NTP For setting the NTP client function. Access to acquire time from the specified NTP server at
regular intervals is possible when this is turned on. In addition, time will be recorded in the JPEG
headers distributed by VN-E4. Discontinuity in JPEG header’s time may occur immediately
before and after acquiring time from the NTP server.
B NTP Server For setting the IP address of the NTP server.
C Interval For setting the time interval for access to the NTP server.
D Time Displays the time on the clock of VN-E4. Clock time may be altered by entering a value and
pressing the AOKB button. However, second value cannot be specified.
Time is recorded in JPEG headers distributed by VN-E4 and therefore discontinuity in JPEG
header’s time may occur immediately before and after changing the time.
E Time Zone For setting the time zone. VN-E4 will reboot when this item is changed. Operation will be
enabled after about 1 minute.
A
B
C
D
E