Kodak 560 Projector User Manual


 
If the flickering problem is still apparent after readjusting the lamp
position, a magnet adjustment may be needed.
1. Please follow all safety precautions listed in this manual for proper
handling of the lamp. You will need to remove the top cover and
operate the projector with the lamp cover off. Please note that the
power interlock switch will need to be depressed in order to keep
the lamp on.
2. Remove the four white screws and lift off the top cover.
3. Locate the black magnet above the reflector. If adjustment is re
quired, loosen the Phillips head screw holding the magnet cylinder
to the bracket.
4. While observing the illuminated screen, slowly turn the magnets
until he flickering stops.
5. Retighten the screw and reinstall the lamp house cover.
The above two procedures should correct any problems you are having
with burning slides and image flickering.
Magnet Adjustment
Solution
Slide Burning & Picture Flicker
19
Flat Mirror
Xenon Bulb
Magnet Assembly
Elliptical Mirror
Housing
Insulation Plate