1. Remove two (2) screws on the side of the dissolve module and take
off the square cover on the dissolve module. Turn on the power
switches for the AVL/Dataton Dissolve Controller and the Navitar
Dissolve Interface unit.
2. Turn off the three set-up switches on your Navitar Dissolve Interface
unit. Rotate the variable resistor C to the position between the
cam and pin as it is shown in the diagram.
3. Turn on the three set-up switches on your Navitar Dissolve Interface
unit. Rotate the variable resistor O to adjust the relationship
between the cam and pin as shown in the diagram.
4. After the above adjustment, repeat the on/off action of the set-up
switch several times and check that the position in each time coin-
cides with the marking. Alternately repeat the adjustment of 2 and
3 until satisfactory results are achieved.
Units with Dissolve Module & Dissolve Interface
23