2
Item Definition Prior confirmation
E-mail TX Setting Select "ON".
Scan to E-mail Select "ON".
SMTP Server Address Specify the SMTP server address. (Format: "***.***.***.***",
Range for ***: 0 to 255)
If the DNS server is specified, the address can be specified
using the host name.
This item can also be specified with IPv6.
Address of the server
Port Number Default setting: 25
Specify the port number.
Port number for the serv-
er
Connection Timeout Specify the time period before the server connection times
out.
Max Mail Size Select whether to limit the size of sent messages.
Server Capacity To limit the maximum mail size, specify the max. allowance
of the mail size including the attached file.
Mails exceeding the maximum allowance are removed.
If a mail is separated, this setting is disabled.
Receiving limit of the
server
Admin. E-mail Address The administrator address specified in "Machine Setting" in
the Maintenance tab in Administrator mode of PageScope
Web Connection is displayed.
Binary Division To divide the mail size, select "ON".
If the mail software used for receiving mails does not have
the mail restore function, the mails may not be read.
Restore function of the
mail soft
Divided Mail Size To divide the mail, specify a divided mail size. Receiving limit of the
server