Lantronix UDS2100 Server User Manual


 
4: Configuration Using Web Manager
Figure 4-7. UDP Connection Settings
Connect Protocol
Protocol Select UDP from the drop-down menu.
Datagram Mode
Datagram Type Configures the remote IP or network broadcast address and
the remote port. Enter 01 for directed or broadcast UDP. The
default setting is 00.
Accept Incoming Select Yes to accept incoming UDP datagrams. The default
setting is Yes.
Endpoint Configuration
Local Port Enter the local port number.
Remote Port Enter the port number of the remote device.
Remote Host Enter the IP address of the remote device.
Use Broadcast Select to broadcast the UDP datagram. Datagrams of type 01
can be sent as a broadcast by enabling this option. The
default is not to broadcast.
Note: Datagrams are sent as subnet-directed broadcasts.
Device Address Table The table is enabled when Datagram Type is set to FD. Enter
values between 1 and 255 to identify units on the local
network of device servers.
Note: Lantronix Tech Support supports Datagram type 01.
Datagram Type FD is for OEM use.
3. When you are finished, click the OK button.
UDS2100 User Guide 34