8: Setup Mode: Advanced Settings
Monitor Mode at bootup
This option allows you to disable all entries into Monitor Mode during startup, except
for the ‘xxx’ sequence. This prevents entry using yyy, zzz, xx1, and yy1 key
sequences (only during the bootup sequence). The default for Monitor Mode at
bootup is N (No). (See
10: Monitor Mode.)
Monitor Mode @ bootup : enabled
HTTP Port Number
This option allows the configuration of the web server port number. The valid range is
1-65535. The default HTTP port number is 80.
HTTP Port Number : (80) ? _
MTU Size
The Maximum Transmission Unit (MTU) is the largest physical packet size a network
can transmit for TCP and UDP. Enter between 512 and 1400 bytes. The default
setting is 1400 bytes.
MTU Size: (1400) ? _
Enable alternate MAC
If necessary, enable the alternate MAC address (if specified in the OEM setup
record). The default setting is N (No).
Enable alternate MAC (N) ? _
Ethernet connection type
The UDS2100 allows for the Ethernet speed and duplex to be manually configured.
Enter 0 for auto-negotiation (default). To select the speed and duplex, enter one of
the following: 2 (10Mbit/half duplex), 3 (10Mbit/full duplex), 4 (100Mbit/half duplex), or
5 (100Mbit/full duplex).
Ethernet connection type: (0) ? _
Security Settings (Option 6)
You can change security settings by means of Telnet or serial connections only, not
on the Web Manager. We recommend that you set security over the dedicated
network or over the serial setup to prevent eavesdropping.
Caution: Disabling both Telnet Setup and Port 77FE will prevent users
from accessing the setup menu from the network. Disabling Port 77FE
also disables the Web Manager from configuring the device.
Select 7 to configure security settings.
UDS2100 User Guide 57