Metrologic Instruments MS7600 Scanner User Manual


 
7
Figure 4: OCIA, Interface
INSTALLATION FOR OCIA INTERFACE
1. Turn off the host system.
2. Connect the MVC cable to the
2
nd
jack down from the top of
the MS7600.
3. Connect the other end of the MVC
cable to the host.
Before continuing verify that the MVC
cable is connected to the appropriate
interface jack on the scanner. An
incorrect cable connection can cause
communication problems or potential
damage to the scanner.
Manufacturers Note:
Plugging the scanner into the serial
port of the PC does not guarantee
that scanned information will appear
at the PC. A software driver and
correct configuration setting are also
required for proper communication to
occur.
4. Turn on the host system.
5. Scan the Load OCIA Defaults bar
code to configure the MS7600 for
OCIA communication.
For additional communication options for OCIA interfaces refer to the
MetroSelect Programming Guide (
MLPN 00-02407A-1 & -2).
Caution:
To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements
for SELV (Safety Extra Low Voltage) according to EN 60950.
To maintain compliance with standard CSA C22.2 No. 60950-00/UL 60950 and norm EN 60950, the power source
should meet applicable performance requirements for a limited power source.
³999993
Load OCIA Defaults