Metrologic Instruments MS7600 Scanner User Manual


 
8
Figure 5: Keyboard Wedge
Interfaces
INSTALLATION FOR KEYBOARD WEDGE INTERFACE
1. Turn of the host system.
2. Disconnect the keyboard from the host.
3. Connect the PowerLink cable to the 2
nd
jack from the top of the MS7600.
4. Connect the “Y” end of the
PowerLink cable to the keyboard
and the keyboard port on the host.
If necessary use the male/female
adapter cable supplied with the scanner
for proper connections.
Before continuing verify that the
PowerLink cable is connected to the
appropriate interface jack on the scanner.
An incorrect cable connection can cause
communication problems or potential
damage to the scanner.
5. Connect the external power supply
to the power jack on the PowerLink cable.
6. Check the AC input requirements
of the power supply to make sure
the voltage matches the AC outlet.
7. Connect AC power to the transformer.
The outlet should be near the equipment
and easily accessible.
8. Scan the Load Keyboard Wedge Defaults
bar code to configure the MS7600 for
Keyboard Wedge communication.
9. Turn on the host system.
Caution:
To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements
for SELV (Safety Extra Low Voltage) according to EN 60950.
To maintain compliance with standard CSA C22.2 No. 60950-00/UL 60950 and norm EN 60950, the power source
should meet applicable performance requirements for a limited power source.
³999994
Load Keyboard
Wedge Defaults