SCANNER AND CABLE TERMINATIONS
Scanner Pinout Connections
The MS7600 scanner interfaces terminate to 10-pin modular jacks located on
the back of the unit. The serial # label indicates the model number of the
scanner.
Figure 20: Scanner Interface Ports
MS762x-13 OCIA MS762x-13 IBM 46xx
Pin Function Pin Function
1 Ground 1 Ground
2 NC 2 RS-232 Transmit Output
3 NC 3 RS-232 Receive Input
4 RDATA 4 RTS Output
5 RDATA Return 5 CTS Input
6 Clock in 6 DTR
7Clock out 7IBM B- (D-)
8
Clock in Return/
Clock out Rtrn
8 IBM A+ (D+)
9+5VDC 9+5V IN
10 Shield Ground 10 NC
MS762x-13/-37 Auxilary Port RS232 IN Only
Pin Function
1 Ground
2 RS-232 Receive Input
3 RS-232 Transmit Output
4 RTS In
5CTS Out
6-10 NC