Monarch 9403 Printer User Manual


 
Using Check Digits
Check digits are typically used to ensure that a text or bar code
field scans correctly. If you apply Option 31, the printer
calculates a check digit. A check digit scheme determines how
the printer calculates a check digit. When you define a check
digit scheme, you assign a number to identify it. This number is
later entered in box
R4
when you apply Option 31 to a field. You
can use check digits with text or bar code fields. Check digit
calculations are performed on numeric data only.
Do not use check digits with price fields. Do not define a check
digit scheme for these bar codes, because they have predefined
check digits: UPC, EAN, Code 39 (with the MOD43 check digit),
and Code 93.
Syntax
{A,selector,action,device,modulus,
fld_length,D/P,"weights" p }
A1. A Check Digit Header.
A2. selector Assign a number from
1-10
to this check digit formula.
A3. action Adds a check digit scheme. Enter
A
.
A4. device Device. Options:
F
Flash (only available for 9403 Version 2.0 or greater)
R
Volatile RAM
NOTE:
Check digits stored in flash are saved when the
printer is turned off.
A5. modulus Number from
2-11
. The modulus is used to divide the sum of
products or the sum of digits.
A6. fld_length The maximum number of characters the field will contain.
Range:
0 - 2710
(
0
-
100
for 9403/9805).
A7. D/P Algorithm. The algorithm determines how the check digit is
calculated.Options:
D
sum of digits
P
sum of products
Defining Field Options
4-19