Fiber Driver
®
EM316SW-XY
PN 1288003-001, Rev D2
37
4.3.5 Chassis Context
Command examples in this section are applied in the chassis-level context. The box below
shows the command to navigate to the chassis context from the login context.
4.3.5.1 “show”
The following CLI excerpt shows a Fiber Driver chassis system with an EM316SW-XY
module and an EM316LNXNM-OT network management (NM) module.
Use the command line “?” (help character, shown below) to display command line
parameters for the show command.
fiberdriver# configure terminal
fiberdriver(config)#
fiberdriver(config)# chassis 1
fiberdriver(chassis/1)#
fiberdriver(chassis/1)#
s
how
Model: NC316BU-16
Name: SOLO
Temp(C): 24
Temp Min(C): 5
Temp Limit(C): 55
PS1: DC Bad PS2: AC Good
Fan1: good Fan2: good
Fan3: good
Chassis Traps: on Slot Change Traps: on Module Specific Traps: on
Port Traps: on Link Traps: on Loopback Traps: on
LIN Traps: on Port Change Traps: on Port Diags Traps: on
Number Of Slots: 16
Hardware Revision: 1
Slot Model Name Serial Number
==== ============= ==================== ============================
1.1 EM316LNXNM-OT EM316LNXNM-OT at 1.1 00:2
1.3 EM316SW-XY EM316SW-XY at 1.3 N/A
0:1a:02:48:28
fiberdriver(chassis/1)#