Fiber Driver
®
EM316SW-XY
PN 1288003-001, Rev D2
65
4.4.4 Switching Mode
MODE1 OFF
MODE0 OFF
P1 and P4 are copper RJ-45 Ethernet ports. P2 and P3 are SFP sockets, so the port specifics
depend upon the SFP transceivers installed. This example shows P1 configured at 10 Mbps
and P4 at 100 Mbps. Only optical SFP port P2 is illustrated because the same variety of SFP is
installed in P2 and P3.
Port P1 (Copper)
fiberdriver# show 1.3
Slot: 1.3
Model: EM316SW-XY
Name: EM316SW-XY at 1.3
Hardware Revision: 1, FPGA 0x68
Sw Configurable: yes Operation Type: switch
Number Of Ports: 4
Port Enable Link Speed DDiags WL(nm) Name
===== ====== ========= ======== ====== ====== ==============
1.3.1 enable link 10 Mbps N/A N/A RJ-45 at 1.3.1
1.3.2 enable link 100 Mbps Ok 1590 SFP at 1.3.2
1.3.3 enable link 100 Mbps Ok 1590 SFP at 1.3.3
1.3.4 enable no Signal 10 Mbps N/A N/A RJ-45 at 1.3.4
fiberdriver#
fiberdriver# show 1.3.1
Port: 1.3.1
Name: RJ-45 at 1.3.1
Protocol: Ethernet
Rate: 10Base-T 10 Mbps
Enable: enable
Link: no Signal Speed: 10 Mbps
MDI Pinout: mdix
Duplex: half MDI Pinout desired: auto Sense
Auto Neg: on
Adv 10Base-T: on
Adv 100Base-Tx: on
Connector: RJ45 Medium: twisted Pair
Rx Activity: off Tx Activity: off
fiberdriver#