Multi Tech Equipment MT5634ZBA-V-V92 Modem User Manual


 
4 AT Commands, S-Registers, & Result Codes
34
MultiModemZBA-V-V92 User Guide
automode
An optional numeric value that enables or disables automatic
modulation negotiation using V.8 bis/V.8 or V.32 bis Annex A.
Automode is disabled if values are specified for the
max_rate
and
max_rx_rate
parameters. The options are:
0 Disable automode
1 Enable automode (default)
max_rate
An optional number that specifies the highest rate at which the
modem may establish an upstream (transmit) connection. The
value is decimal coded in units of bps, for example, 33600
specifies the highest rate to be 33600 bps.
0 Maximum rate determined by the modulation selected in
mod
(default).
30033600 Maximum rate value limited by the modulation selected in
mod
.
For valid
max_rate
values for each
mod
value, see the follow-
ing table.
V21, Bell103 300
V22, V23C, Bell212A 1200
V22B 2400
V32 14400, 12000, 9600, 7200, 4800
V32B 19200, 16800, 14400, 12000, 9600, 7200, 4800
V92, V90, V34 33600, 31200, 28800, 26400, 24000, 21600,19200, 16800,
14400, 12000, 9600, 7200, 4800, 2400
mod value Valid max_rate values (bps)
max_rx_rate
An optional number that specifies the highest rate at which the
modem may establish a downstream (receive) connection. The
value is decimal coded in units of bps, e.g., 28800 specifies the
highest rate to be 28800 bps.
0 Maximum rate determined by the modulation selected in
mod
(default).
30056000 Maximum rate value limited by the modulation selected in
mod
.
See Possible rates in the
mod
table.
Command: +PCW=
n
Call Waiting Enable
Values:
n
= 0, 1, or 2
Default: 2
Description: Controls the action to be taken upon detection of a call waiting
tone in V.92 mode. Values specified by this command are not
modified when an AT&F command is issued.
+PCW=0 Toggles V.24 Circuit 125 and collects Caller ID if enabled by
+VCID
+PCW=1 Hangs up
+PCW=2 Ignores V.92 call waiting
+PCW=? Displays the allowed values
+PCW? Displays the currrent value