Multi Tech Equipment MT5634ZBA-V-V92 Modem User Manual


 
A Regulatory Compliance
85
MultiModemZBA-V-V92 User Guide
5. Warning Notice: No 111 or other calls can be made from this device during a mains power
failure.
6. This equipment may not provide for the effective hand-over of a call to another device connected
to the same line.
7. Some parameters required for compliance with Telecoms Telepermit requirements are
dependent on the equipment (PC) associated with this device. The associated equipment shall
be set to operate within the following limits for compliance with Telecoms Specifications:
For repeat calls to the same number:
There shall be no more than 10 call attempts to the same number within any 30-minute period
for any single manual call initiation, and
The equipment shall go on-hook for a period of not less than 30 seconds between the end of
one attempt and the beginning of the next attempt.
For automatic calls to different numbers:
The equipment shall be set to ensure that automatic calls to different numbers are spaced
such that there is no less than 5 seconds between the end of one call attempt and the
beginning of another.
For automatically answered incoming calls:
The equipment shall be set to ensure that calls are answered between 3 and 30 seconds of
receipt of ringing.
8. For correct operation, total of the RNs of all devices connected to a single line at any time should
not exceed 5.
South African Notice
This modem must be used in conjunction with an approved surge protection device.