Multi Tech Equipment MT5634ZBA-V-V92 Modem User Manual


 
6 Callback Security
61
MultiModemZBA-V-V92 User Guide
6. After the modems reconnect, the following message reappears:
Password>
7. Type the same password that you used to initiate the call. You have three attempts to enter the
password or be disconnected.
8. If the password is valid, the following message appears and the modems establish a working
connection:
OK Connecting
Extension-Entry Callback
Use this procedure when calling from an extension at the callback number. The password that you
use must be set up for an optional extension-entry callback.
1. Using a data communications program such as HyperTerminal or PhoneTools, dial the number
of the callback modem.
2. When the connection is established, the callback modem responds with the following message:
Password>
3. Type an extension-entry password, press the plus key (+), type the extension to call back to, and
press ENTER. You have three attempts or one minute to enter a valid password.
4. If the password is valid, the following message appears, and the modems disconnect:
OK Disconnecting
5. After the delay specified by the #CBD
n
command, the callback modem calls the extension that
you entered after the + character. If the callback modem is unable to establish a connection, it
tries again, up to the number of attempts specified by the #CBA
n
command.
6. After the modems reconnect, the following message reappears:
Password>
7. Type the same password you used to initiate the call. You have three attempts to enter the pass-
word or be disconnected.
8. If the password is valid, the following message appears, and the modems establish a working
connection:
OK Connecting