Appendix A Specifications
NI 7831R User Manual A-8 ni.com
chassis, tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2
Relative humidity range..........................10 to 90%, noncondensing, tested
in accordance with
IEC-60068-2-56
Altitude...................................................2,000 m at 25 °C ambient
temperature
Storage Environment
Ambient temperature range ....................–20 to 70 °C tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2
Relative humidity range..........................5 to 95%, noncondensing, tested
in accordance with
IEC-60068-2-56
Note Clean the device with a soft, non-metallic brush. Make sure that the device is
completely dry and free from contaminants before returning it to service.
Shock and Vibration (for NI PXI-7831R Only)
Operational Shock ..................................30 g peak, half-sine, 11 ms pulse
Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.
Random Vibration
Operating.........................................5 to 500 Hz, 0.3 g
rms
Nonoperating...................................5 to 500 Hz, 2.4 g
rms
Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.