NetComm NP2624M Switch User Manual


 
6 NP2624M User Guide
YML827 Rev1
1.3 Initial set up for management
There are two methods of management; one is out-of-band management, where you connect your
PC to the switch through an RS232 cable. The other method is in-band-management, where you also
connect your PC to the switch, but do so through an Ethernet network either locally or remotely,
or simply directly connect your PC and the switch with an Ethernet cable. Before you activate the
management function in the Switch, you should read the instructions below carefully to ensure you
can access the switch through your PC.
1.3.1 Out-of-band Terminal Mode Management through RS-232
Step 1: Set Hyper Terminal parameters on your PC
Firstly, turn on your PC and execute a terminal mode program. For example, if you are in a
Microsoft Window environment, you may choose “Hyper Terminal” from programs that are
listed for communication.
Open a New Connection using COM1 (or the port on your computer that you are going to
connect the Switch to) and select the following port settings:
Bits Rate per second = 57600
Data Bits = 8
Parity = None
Stop Bit = 1
Flow Control = None
Step 2: Access your Switch
After setting the above parameters on your PC, connect your switch device with the RS-232
cable provided and turn the switch on. After the switch runs its self-test, the device should
respond and ask you to enter the username and password. If the switch had already booted,
press the enter key to display the login screen. Type the default value for the username and
password to proceed, the default username is “admin” and default password “admin”. To
learn more about the operation of the Switch in this mode, refer the instructions in chapter 4
of this manual.